====== MitsuRunner introduction ====== | ====== MitsuRunner introduction ====== | ||
- | Software for ESP8266 or ESP32 based device | + | Software for ESP8266 or ESP32 based devices |
- | Many Finns suffer from poor design of Mitsubishi heat pumps. In normal winter at -15 c degrees especially MSZ-LN series | + | Many Finns suffer from the poor design of Mitsubishi heat pumps. In normal winter at -15 c degrees especially MSZ-LN series de-frosts |
===== Background ===== | ===== Background ===== | ||
- | This software started from topic in lampopumput.info forum: https:// | + | This software started from a topic in the lampopumput.info forum: https:// |
- | The design of these Mitsubishi MZN-LN25/35 etc. heatpumps is poor both in software and in mechanics. **The software in the unit does not suit for the Finnish climate - and most probably not to any climate where pump needs to be used for heating and temperature goes below -5 degrees.** The pump heats mainly with short cycles (under 60 minutes) and tries to melt ice from outdoor unit's heat exhanger even there is no ice. This is waste of energy and makes heating inefficient. | + | The design of these Mitsubishi MZN-LN25/35 etc. heatpumps is poor both in software and mechanically. **The software in the unit does not suit the Finnish climate - and most probably not any climate where the pump needs to be used for heating and the temperature goes below -5 degrees.** The pump heats mainly with short cycles (under 60 minutes) and tries to melt ice from outdoor unit's heat exhanger even when there is no ice. This is a waste of energy and makes heating inefficient. |
- | This is due to poor "fuzzy logic" algorithm which: | + | This is due to the poor "fuzzy logic" algorithm which: |
- | * Instead of using temperature sensors it tries to predict de-frost need from previous cycles | + | * Instead of using temperature sensors it tries to predict de-frost need from previous cycles. |
- | * The mechanical side probems are related to defrost temperature sensor. It is used to detect when the ice has melt from outdoor heat exhanger. The defrost temperature sensor is installed poorly so it touches non-waterproof insulation material which gets wet from melting water/ | + | * The mechanical side of the probems are related to the defrost temperature sensor. It is used to detect when the ice has melted |
- | * Also looks like Mitsubishi has limited temperature sensor' | + | * Also looks like Mitsubishi has limited |
===== Operation principle ===== | ===== Operation principle ===== | ||
- | MitsuRunner cheats heat pump by switching a 33k resistor in place of de-frost thermistor (measuring outdoor unit's heat exchanger' | + | MitsuRunner cheats |
==== Harwdare shopping list ==== | ==== Harwdare shopping list ==== |