MitsuRunner introduction

Software for ESP8266 or ESP32 based devices designed to prevent Mitsubishi Electric heatpumps from doing too short heating runs and de-frosting the outdoor unit every 30 minutes or so. This .yaml file is designed for https://ESPhome.io, which is needed to generate, compile and update sources. Please follow the information on their site how to set-up environments.

Many Finns suffer from the poor design of Mitsubishi heat pumps. In normal winter at -15 c degrees especially MSZ-LN series de-frosts every 30/40 minutes even when there is practically no frost in the outdoor unit, ie. no need to defrost. Frequent de-frosting leads to poor heat production and most likely very poor effiency (“COP”) compared to a unit where defrost happens only once every 2-3 hours under the same conditions.

Background

This software started from a topic in the lampopumput.info forum: https://lampopumput.info/foorumi/threads/msz-ln-sulatushuijaus.31223/

The design of these Mitsubishi MZN-LN25/35 etc. heatpumps is poor both in software and mechanically. The software in the unit does not suit the Finnish climate - and most probably not any climate where the pump needs to be used for heating and the temperature goes below -5 degrees. The pump heats mainly with short cycles (under 60 minutes) and tries to melt ice from outdoor unit's heat exhanger even when there is no ice. This is a waste of energy and makes heating inefficient.

This is due to the poor “fuzzy logic” algorithm which:

Operation principle

MitsuRunner cheats the heat pump by switching a 33k resistor in place of de-frost thermistor (measuring outdoor unit's heat exchanger's temperature) of the heat pump. That makes the heat pump think that the temperature is above zero celsius and there is no need to de-frost. MitsuRunner itself uses two thermistors to measure the temperature difference (delta) between the outdoor heat exchanger and the outdoor air. When the difference (delta) is big enough, it switches the heat pump's real de-frost thermistor back and lets the heat pump de-frost. After de-frosting the 33k resistor is switched back until MitsuRunner triggers the next de-frost.

Harwdare shopping list

And some basic hardware store items like