en:puus_setup
Differences
This shows you the differences between two versions of the page.
| Both sides previous revisionPrevious revisionNext revision | Previous revision | ||
| en:puus_setup [2023/01/10 16:39] – puu | en:puus_setup [2023/02/06 12:16] (current) – [Outdoor heat exchanger sensor] puu | ||
|---|---|---|---|
| Line 1: | Line 1: | ||
| ====== puu's MitsuRunner setup ===== | ====== puu's MitsuRunner setup ===== | ||
| - | ===== Mitsurunner wiring ===== | + | * My slightly modified MitsuRunner software on GitHub: https:// |
| - | ==== Outdoor unit opened ==== | + | Notable changes to the original SW and HW: |
| - | {{: | + | * Two additional Dallas sensors in heat exchanger pipes (used for research and as spare parts) |
| + | * Current clamp sensor monitoring input power of the heat pump | ||
| + | * Variable temperature delta threshold to start defrosting: | ||
| + | * if (input) power < 500W, threshold | ||
| + | * if 900W <= power < 1000W, threshold | ||
| + | * if power >= 1000W, threshold | ||
| + | \\ \\ | ||
| + | ---- | ||
| - | ==== Defrost thermistor' | + | ===== MitsuRunner wiring ===== |
| - | {{: | + | |
| + | ==== Defrost thermistor' | ||
| + | {{: | ||
| + | {{: | ||
| + | \\ \\ | ||
| ==== Defrost hack wires installed ==== | ==== Defrost hack wires installed ==== | ||
| - | {{:en: | + | {{: |
| - | + | {{: | |
| - | {{:en: | + | \\ \\ |
| ==== MitsuRunner' | ==== MitsuRunner' | ||
| - | {{:en: | + | {{: |
| + | \\ \\ | ||
| ---- | ---- | ||
| ===== Sensors ===== | ===== Sensors ===== | ||
| - | ==== Outdoor heat exchanger | + | ==== Outdoor heat exchanger sensor ==== |
| - | {{:en: | + | Outdoor heat exchanger sensor (vertically installed on the lowest pipe) and two additional sensors just in case |
| + | {{: | ||
| + | {{: | ||
| + | \\ \\ | ||
| + | ==== Middle DS18B20 is used for MitsuRunner, | ||
| + | {{: | ||
| + | \\ \\ | ||
| ==== Outdoor temperature sensor ==== | ==== Outdoor temperature sensor ==== | ||
| - | {{:en: | + | {{: |
| - | + | {{: | |
| - | {{:en: | + | \\ \\ |
| - | + | ||
| - | ==== Spare sensor on upper pipe ==== | + | |
| - | {{: | + | |
| ---- | ---- | ||
| ===== Enclosure ===== | ===== Enclosure ===== | ||
| - | {{:en: | + | {{: |
| - | + | {{: | |
| - | {{:en: | + | {{: |
| - | + | \\ \\ | |
| - | {{:en: | + | |
| - | + | ||
| ---- | ---- | ||
| Line 48: | Line 55: | ||
| ==== Defrost thermistor insulated ==== | ==== Defrost thermistor insulated ==== | ||
| - | {{:en: | + | {{: |
| + | \\ \\ | ||
| ==== Holes drilled to avoid ice accumulating ==== | ==== Holes drilled to avoid ice accumulating ==== | ||
| - | {{:en: | + | {{: |
en/puus_setup.1673361541.txt.gz · Last modified: 2023/01/29 21:54 (external edit)