| - | * My Mitsurunner | + | * My slightly modified MitsuRunner |
| + | Notable changes to the original SW and HW: | ||
| + | * Two additional Dallas sensors in heat exchanger pipes (used for research and as spare parts) | ||
| + | * Current clamp sensor monitoring input power of the heat pump | ||
| + | * Variable temperature delta threshold to start defrosting: | ||
| + | * if (input) power < 500W, threshold = 4 | ||
| + | * if 900W <= power < 1000W, threshold = 5 | ||
| + | * if power >= 1000W, threshold = 6 | ||
| + | \\ \\ | ||
| ---- | ---- | ||
| - | ===== Mitsurunner | + | ===== MitsuRunner |
| - | ==== Outdoor | + | ==== Defrost thermistor' |
| {{: | {{: | ||
| - | |||
| - | ==== Defrost thermistor' | ||
| {{: | {{: | ||
| + | \\ \\ | ||
| ==== Defrost hack wires installed ==== | ==== Defrost hack wires installed ==== | ||
| {{: | {{: | ||
| {{: | {{: | ||
| + | \\ \\ | ||
| ==== MitsuRunner' | ==== MitsuRunner' | ||
| {{: | {{: | ||
| + | \\ \\ | ||
| ---- | ---- | ||
| ===== Sensors ===== | ===== Sensors ===== | ||
| - | ==== Outdoor heat exchanger | + | ==== Outdoor heat exchanger sensor ==== |
| + | Outdoor heat exchanger sensor (vertically installed on the lowest pipe) and two additional sensors just in case | ||
| {{: | {{: | ||
| + | {{: | ||
| + | \\ \\ | ||
| + | ==== Middle DS18B20 is used for MitsuRunner, | ||
| + | {{: | ||
| + | \\ \\ | ||
| ==== Outdoor temperature sensor ==== | ==== Outdoor temperature sensor ==== | ||
| {{: | {{: | ||
| {{: | {{: | ||
| - | + | \\ \\ | |
| - | ==== Spare sensor on upper pipe ==== | + | |
| - | {{: | + | |
| ---- | ---- | ||
| Line 41: | Line 49: | ||
| {{: | {{: | ||
| {{: | {{: | ||
| - | + | \\ \\ | |
| ---- | ---- | ||
| Line 49: | Line 56: | ||
| ==== Defrost thermistor insulated ==== | ==== Defrost thermistor insulated ==== | ||
| {{: | {{: | ||
| + | \\ \\ | ||
| ==== Holes drilled to avoid ice accumulating ==== | ==== Holes drilled to avoid ice accumulating ==== | ||
| {{: | {{: | ||