en:puus_setup [2023/01/13 07:55] puuen:puus_setup [2026/08/05 09:00] (current) puu
Line 2: Line 2:
  
   * My slightly modified MitsuRunner software on GitHub: https://github.com/kestopuu/mitsurunner/   * My slightly modified MitsuRunner software on GitHub: https://github.com/kestopuu/mitsurunner/
 +
 +**[[https://www.youtube.com/watch?v=iBc9BkL0kBM|Video (speaking in Finnish)]]**
  
 Notable changes to the original SW and HW: Notable changes to the original SW and HW:
Line 7: Line 9:
   * Current clamp sensor monitoring input power of the heat pump   * Current clamp sensor monitoring input power of the heat pump
   * Variable temperature delta threshold to start defrosting:   * Variable temperature delta threshold to start defrosting:
-    * if (input) power < 900W, threshold = 4 +    * if (input) power < 500W, threshold = 4 
-    * if 900W <= power < 1400W, threshold = 5 +    * if 900W <= power < 1000W, threshold = 5 
-    * if power >= 1400W, threshold = 6 +    * if power >= 1000W, threshold = 6 
 + \\ \\ 
 ---- ----
  
-===== Mitsurunner wiring =====+===== MitsuRunner wiring =====
  
 ==== Defrost thermistor's wires inside the outdoor unit ==== ==== Defrost thermistor's wires inside the outdoor unit ====
 {{:1613833132673.jpg?direct&600|}} {{:1613833132673.jpg?direct&600|}}
 {{:1613833227097.jpg?direct&600|}} {{:1613833227097.jpg?direct&600|}}
 + \\ \\ 
 ==== Defrost hack wires installed ==== ==== Defrost hack wires installed ====
 {{:1613833279863.jpg?direct&600|}} {{:1613833279863.jpg?direct&600|}}
 {{:1613833353619.jpg?direct&600|}} {{:1613833353619.jpg?direct&600|}}
 + \\ \\ 
 ==== MitsuRunner's AC wires and current measurement clamp ==== ==== MitsuRunner's AC wires and current measurement clamp ====
 {{:1628058938369.jpg?direct&600|}} {{:1628058938369.jpg?direct&600|}}
 + \\ \\ 
 ---- ----
  
 ===== Sensors ===== ===== Sensors =====
  
-==== Outdoor heat exchanger sensor (diagonally installed) and two additional sensors just in case ====+==== Outdoor heat exchanger sensor ==== 
 +Outdoor heat exchanger sensor (vertically installed on the lowest pipe) and two additional sensors just in case
 {{:1628058538905.jpg?direct&600|}} {{:1628058538905.jpg?direct&600|}}
 {{:1628058554351.jpg?direct&600|}} {{:1628058554351.jpg?direct&600|}}
 + \\ \\ 
 ==== Middle DS18B20 is used for MitsuRunner, blue arrow points to the location of the original defrost thermistor ==== ==== Middle DS18B20 is used for MitsuRunner, blue arrow points to the location of the original defrost thermistor ====
 {{:1628143146973.jpg?direct&600|}} {{:1628143146973.jpg?direct&600|}}
 + \\ \\ 
 ==== Outdoor temperature sensor ==== ==== Outdoor temperature sensor ====
 {{:1628059042729.jpg?direct&600|}} {{:1628059042729.jpg?direct&600|}}
 {{:1628083497222.jpg?direct&600|}} {{:1628083497222.jpg?direct&600|}}
 + \\ \\ 
 ---- ----
  
Line 48: Line 51:
 {{:1628058837331.jpg?direct&600|}} {{:1628058837331.jpg?direct&600|}}
 {{:1628059021262.jpg?direct&600|}} {{:1628059021262.jpg?direct&600|}}
- + \\ \\ 
 ---- ----
  
Line 56: Line 58:
 ==== Defrost thermistor insulated ==== ==== Defrost thermistor insulated ====
 {{:1628058402250.jpg?direct&600|}} {{:1628058402250.jpg?direct&600|}}
 + \\ \\ 
 ==== Holes drilled to avoid ice accumulating ==== ==== Holes drilled to avoid ice accumulating ====
 {{:1628058345389.jpg?direct&600|}} {{:1628058345389.jpg?direct&600|}}
  
en/puus_setup.1673596532.txt.gz · Last modified: 2023/01/29 19:54 (external edit)